Modular Buildings
Fire Safety System

As the UK attempts to meet the demand for housing, modular properties are offering an innovative solution – providing housing with great design, quality and cost.

Innovative Fire Protection Solutions

Modular buildings are usually manufactured and designed off-site, in their own factories. In such circumstances, iMist™ Fire Suppression systems are fitted in the factory to ensure that every detail is perfect and then, once the home is transported to the site and in its final position, additional works are carried out.

iMist™ Fire Suppression systems are ideal for modular builds as they are installed quickly, with minimum disruption, and they ensure the modular factory suffers no delay in production. Reduced water usage, in the event of an activation, protects the property from post-fire water damage and minimises disruption to residents.
 

 

Water Mist Systems
hotels and hostels fire safety

Why is a Fire Suppression System needed?

BSI: 9991 says you must have an AWFSS in the following circumstances;

 

5.2.1.2 Multi-Basement Buildings
For dwellings with multiple floors below ground level, a protected stairway, and an AWFSS, 9m meters should not be exceeded for from the foot of the
protected stair to any habitable room

6.4 (b) Dwelling Houses with one or more storey greater than 7.5m in height (4 storeys)

A second, separate protected stairwell is not required if AWFSS is fitted throughout.

9.1 (d) Internal Planning of Flats and Maisonettes

Flats or maisonettes with an open plan arrangement and more than one floor should have a protected stairway and AWFSS fitted. This allows escape to the shared external entrance.

9.4.2 (a) Extended travel distances within an open-plan flat

Flats more than 4.5m above ground level that are entered on the same level can increase total travel distances to the entrances from 9m to 20m with the
use of AWFSS throughout the entire building, along with a LD1 fire detection and fire alarm system in accordance with BS 5839-6:2013.

9.3 (b) Provision of inner rooms in flats not more than 4.5m in height

Inner rooms are not suggested unless the use of an AWFSS is utilised throughout the entire building, along with a grade D LD1 Fire detections and fire alarm system in accordance with BS 5839-6:2013.

9.7 Open Plan Layouts

Open planned flats are permissible with a fully fitted AWFSS.

Benefits to the iMist™ system

Water Mist Fire Suppression Systems have been increasing in popularity due to the ease of the system and the multiple benefits, especially when compared to other fire suppression alternatives.

Free Quotation Package

Our designers will return your quotation and design within 24 hours to ensure a quick start to your project.

Certified, Audited and Approved

We have worked hard to obtain and pass third-party accreditations for installations, designs and manufacturing.

All iMist™ Employees

Everything we do is completed directly by iMist™ employees who have been fully trained in-house and have the competence to complete projects.

Over 180 Years of Knowledge

Our combined years of engineering knowledge will ensure that your project is always in the best hands.

Get a FREE quote today regarding your modular building project

View our case studies